Abstract

Condition monitoring of power transformers improves the reliability and the safety of an electrical power system. It protects the transformers from fire hazards, and avoids a huge revenue loss to the utilities. The health status of transformers is decided by their several influencing factors. An accurate health assessment of transformers based on various influencing factors has been a challenging task for the researchers as well as the diagnostic experts. In the present paper, a new multi-criterion technique for assessing the health condition of the transformers has been proposed. The main aspects of transformers have been taken into consideration in evaluating their present health status. The overall outcome of the proposed model depends upon all considered attributes as a whole, but not on any single attribute. Hence the proposed approach determines the more reliable and accurate health condition of transformers. It removes the over influence of the attributes in an exact decision making. It also overcomes the shortcomings of the conventional health assessment methods of transformers. Final calculated factors imply what kind of action needs to be implemented for optimal performance and life extension of the transformers.

Keywords

Transformer, Attribute, Health, Condition Monitoring, Multi-Criteria, Insulation

How to Cite this Article?

Ranga, C., Chandel, A. K., and Chandel, R. (2016). Multi-Attributes Based Health Assessment of Power Transformers. i-manager’s Journal on Power Systems Engineering, 4(3), 28-38. https://doi.org/10.26634/jps.4.3.8269

References

[1]. Jahromi, A., Piercy R., Cress S., and Fan W. (2009). “An approach to power transformer asset management using health index”. IEEE Electrical Insulation Magazine, Vol.25, pp.20-34.
[2]. Dominelli, N. (2004). “Equipment Health Rating of Power Transformers”. IEEE International Symposium on Electrical Insulation, pp. 163-168.
[3]. Gorgan, B., Notingher, P., Badicu, L., and Tanasescu, G. (2010). “Calculation of power transformers health indexes”. Electrical Engineering Series, Vol.34, pp.13-18.
[4]. Xiang, Z., and Gockenbach, E. (2008). “Asset management of transformers based on condition monitoring and standard diagnosis”. IEEE Electrical Insulation Magazine. Vol.24, pp.26-40.
[5]. Spacek, J. (2008). “Maintenance strategies of power equipments with a brief view to condition monitoring of power transformers”. International Conference on Modern Technique and Technologies (MTT), pp. 16-19.
[6]. Lelekajis, A., and Martin, D. (2007). “Comparision of dissolved gas in oil analysis methods using a dissolved gas in oil standard”. IEEE Electrical Insulation Magazine. Vol.27, pp.1-5.
[7]. Yuan, Z., and Chen, M. (2010). “Make use of water and furfural to carry out transformer aging estimation”. IEEE Electrical Insulation Magaine, Vol.22, pp.1-3.
[8]. Piotr, P., and Hanna, M. (2010). “The influence of water content and ageing degree of paper insulation on its mechanical strength”. International Conference on Solid Dielectrics, Vol.5, pp.1-3.
[9]. Rahi, O. P., Chandel, A. K., and Sharma, M. G. (2010). “Refurbishment and up rating of Old Hydro Power Plants”. Indian Journal of Power and River Valley Development. Vol.2, pp.143-147.
[10]. Milan, Z. (1975). Multiple Criterion Decision Making. Tata McGraw-Hill: Delhi.
[11]. Magie, J. F. (1964). Decision Trees for Decision Making. Harvard Business Review.
[12]. Schultz, R. L. (1980). “Descriptive decision making and its applications”. In Applications of Management Science (JAI Press).
[13]. Stewart, T. J. (1997). Scenario Analysis and Multicriteria Decision Making. Springer, Berlin, pp.519-528.
[14]. International Energy Agency, (2004). Guidelines for Hydroelectric Generator Upgrading.
[15]. IEA, (2001). Guidelines on Methodology for Hydroelectric Francis Turbine upgrading by Runner Replacement.
[16]. Tang, W. H., and Hu, W. (2011). Condition Monitoring and Assessment of Power Transformers using Computational Intelligence. London: ISBN 978- 0857290519.
[17]. Han, Y., and Song, Y. H. (2003). “Condition Monitoring Techniques for Electrical Equipment- A Literature Survey”. IEEE Transactions on Power Delivery. Vol.18, pp.4-13.
[18]. Fofana, I., and Borsi, H., Gockenbach, E., Farzaneh, M. (2006). “Ageing of transformer insulating materials under selective conditions”. European Transactions on Electric Power. pp.1-21.
[19]. Shintemiro, A., Tang, W. A., and Wu, Q. H. (2010). “Improved modelling of power transformer winding using bacterial swarming algorithm and frequency response analysis”. Electric Power Systems Research. Vol.80, pp.1111-1120.
[20]. Wang, H., and Butler, K. L. (2001). “Finite element analysis of internal winding faults in distribution transformers”. IEEE Transactions on Power Delivery. Vol.16, pp.1321-1329.
[21]. CIGRE Working Group, (1983). “An international survey on failures in large power transformers in service”. Electra, pp.88-96.
[22]. Wang, M., and Vandermaar, A. J. (2001). “Review of condition assessment of power transformers in service”. IEEE Electrical Insulation Magazine. Vol.18, pp.12-25.
[23]. Persson, C., and Stevenson, J. O. (2001). “Replacement and refurbishment strategies for transformer populations”. CIGRE Colloquium, pp.12-20.
[24]. IEC Publication 60567, (1992). Guide for the Sampling of Gases and Oil from Oil-filled Electrical Equipment and for the Analysis of Free and Dissolved Gases.
[25]. Noonan, T. (2000). “Power transformer on-site condition assessment testing”. International Council on Large Electric Systems, (CIGRE), Paris, France.
[26]. Brooks, R. S., and Urbani, G. S. (1998). “Using the recovery voltage method to evaluate aging in oil-paper insulation”. IEEE Int. Conf. Conduction and Breakdown in Solid Dielectrics, Vasteras, Sweden, pp.93-97.
[27]. Thomas, P., and Shukla, A. K. (2001). “Aging studies on paper – oil to assess the condition of solid insulation th used in power transformers”. IEEE 7 Int. Conf. Solid Dielectrics, Eindhoven: the Netherlands.
[28]. Borsi, H., and Gockenbach, E. (2007). “Monitoring, diagnosis and life management of power transformers”. Conf. Maintenance Operation high-Voltage Electrical Equipment, Sydney: Australia.
[29]. IEEE Std. IEEE Guide for Protective Relay Applications to Power Transformers. C37.91-2000.
[30]. Webster, J., (1999). Encyclopedia of Electrical and Electronics Engineering, John Wiley & Sons.
[31]. Oliveira, L. M., and Marques, A. J. (2002). “On-line diagnostics of transformer winding insulation failures by Park's vector approach”. International Electrical Insulation Conference, Berlin-Germany, pp.16-21.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.