Distribution Systems Reliability Analysis with Power Quality issues and Neutral Currents Compensation Mistreatment MLI-DSTATCOM

T. Rakesh*, V. Madhusudhan**, M. Sushama***
* Research Scholar, Department of Electrical and Electronics Engineering, Jawaharlal Nehru Technical University, Hyderabad, India.
** Principal & Dean, Kandula Obul Reddy Memorial College of Engineering, Kadapa, India.
** Professor, Department of Electrical and Electronics Engineering, Jawaharlal Nehru Technical University, Hyderabad, India.
Periodicity:March - May'2016
DOI : https://doi.org/10.26634/jcir.4.2.8097

Abstract

The “Multilevel Converter” has a massive interest at intervals for the vigour programs enterprise. The fundamental constitution of the construction converter is to decompose a curving voltage from some stages of voltages. Construction voltage offer converters area unit manufacturing as a latest breed of energy converter choice for prime energy applications. These converter topologies will generate high-quality voltage waveforms with vigor semiconductor switches acting at a frequency shut. Among the three construction converter topologies, the five-level and 7-level construction convertors constitute a promising replacement, providing a standard style that will be extended to permit an electrical device-less affiliation. This paper offers a three-segment, five stages and 7 stages cascaded construction voltage supply electrical converter headquartered DSTATCOM for vigour line learning to create stronger vigour satisfactory at intervals of the distribution network. Eventually, a curving PWM (SPWM) procedure is adopted to look at the potency of MLI based DSTATCOM. The outcomes the area unit brought by suggests that of Mat science lab / Simulink application package deal.

Keywords

Distribution STATCOM (DSTATCOM), Matlab/Simulink, Energy Great Issues, Multi-Degree Inverter

How to Cite this Article?

Rakesh, T., Madhusudhan, V., and Sushama, M. (2016). Distribution Systems Reliability Analysis with Power Quality issues and Neutral Currents Compensation Mistreatment MLI-DSTATCOM. i-manager’s Journal on Circuits and Systems, 4(2), 1-16. https://doi.org/10.26634/jcir.4.2.8097

References

[1]. Bhim Singh, Kamal Al-Haddad and Ambrish Chandra, (1999). “A New Control Approach to 3-phase Active Filter for Harmonics and Reactive Power Compensation”. IEEE Trans. on Power Systems, Vol. 46, No. 5, pp.133-138.
[2]. W. K. Chang, W. M. Grady, Austin, and M. J. Samotyj, (1994). “Meeting IEEE-519 Harmonic Voltage and Voltage Distortion Constraints with an Active Power Line Conditioner”. IEEE Trans on Power Delivery, Vol. 9, No. 3, pp. 1531-1537.
[3]. Hirofumi Akagi, (1994). “Trends in Active Power Line Conditioners”. IEEE Trans on Power Electronics, Vol.9, No.3, pp. 263-268.
[4]. S.K. Meeravali, and K. Chandrasekhar, (2015). “Power Quality Enhancement using Multi-Level Cascaded HBridge Based D-STATCOM with IRP Theory”. International Electrical Engineering Journal (IEEJ), Vol. 6, No. 2, pp. 1756- 1764.
[5]. O. Anaya-Lara, and E. Acha, (2002). “Modeling and Analysis of Custom Power Systems by PSCAD/EMTDC”. IEEE Trans. Power Delivery, Vol. 17, No. 1, pp. 266-272.
[6]. S.V. Ravi Kumar, and S. Sivanagaraju, (2007). “Simualgion of D-Statcom and DVR in Power System”. ARPN Journal of Engineering and Applied Science, Vol. 2, No. 3, pp. 7-13.
[7]. Noramin Ismail, and Wan Norainin Wan Abdullah, (2010). “Enhancement of Power Quality in Distribution th System using D-STATCOM”. The 4 International Power Engineering and Optimization Conference (PEOCO2010), Shah Alam, Selangor, Malaysia. pp. 23-24.
[8]. G. Venkataramana, and B. Johnson, (1997). “A Pulse Width Modulated Power Line Conditioner for Sensitive Load Centers”. IEEE Trans. Power Delivery, Vol. 12, No. 2, pp. 844-849.
[9]. Rosli Omar, Nasrudin Abd Rahim and Mazizan Sulaiman, (2008). “Modeling and Simulation for Voltage Sags/Swells Mitigation using Dynamic Voltage Restorer (DVR)”. Journal of Theoretical and Applied Information Technology, pp. 464-470.
[10]. Bhattacharya Sourabh, (2012). “Applications of DSTATCOM using MATLAB/Simulation in Power System”. Research Journal of Recent Sciences, Vol. 1, pp. 430-433.
[11]. Rodda Shobha Rani, and B. Jyothi, (2011). “VSC Based DSTATCOM & Pulse-Width Modulation for Power Quality Improvement”. International Journal of Engineering Trends and Technology, Vol. 2, No. 2, pp. 38-41.
[12]. M. Mohammadi, and M. Akbari Nasab, (2011). “Voltage Sag Mitigation with D-STATCOM in Distribution Systems”. Australian Journal of Basic and Applied Sciences, Vol. 5, No. 5, pp. 201-207.
[13]. Zhang Bao-hui, Wang Li-yong, Zhang Wen-hao, Zhou De-cai, Yao Feng, Ren Jin-feng, Xie Han, and Yu Gangliang, (2005). “Implementation of Power System Security and Reliability Considering Risk Under Environment of Electricity Market”. IEEE/PES Transmission and Distribution Conference & Exhibition: Asia and Pacific Dalian, China.
[14]. Ignacio Hernando-Gil,Irinel-Sorin Ilie, and Sasa Z. Djokic, (2016). “Reliability Planning of Active Distribution Systems Incorporating Regulator Requirements and Network-reliability Equivalents”. IET Gener. Transm. Distrib., Vol. 10, No. 1, pp. 93-106.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.