Lung Function Assessment for Asthma Treatment by Interfacing of Sensors with Android App

Manikandan*, Sivashankaran**, Sathis kumar C***, Kanagaraj****
* Assistant Professor, Department of Electronics and Communication Engineering, Jay shriram group of institutions, Tirupur.
**-***-**** Student, Department of Electronics and Communication Engineering, Jay shriram group of institutions, Tirupur.
Periodicity:December - February'2014
DOI : https://doi.org/10.26634/jcom.1.4.2714

Abstract

Asthma is a disease that affects over 300 million people worldwide and is disproportionately observed in the developing world where air pollution is sometimes more prevalent [1]. This disease can range in severity, causing the airways of the lungs to constrict and inflame, and the therapies can completely and permanently ameliorate the disease's effects on the respiratory system. One effective way to track the asthma symptoms is to monitor a patient's Peak Expiratory Flow (PEF). There are presently many different handheld PEF monitors commercially available, and these suffer from a variety of different limitations. Many current PEF meters are inaccurate, inconvenient to use, bulky, expensive, and rarely include real-time data plotting capabilities. The authors have created a user- friendly, accurate, and moderately inexpensive external mobile device accessory that records and stores the user's PEF, and graphs this data over time. They also have created a custom software interface to send this stored data electronically.

Keywords

Asthma, Peak Expiratory Flow (PEF), Personal Mobile Devices, Respiratory Diagnostics, Respiratory Rate (RR), Beats Per Minute (bpm), Breaths Per Minute (bpm)

How to Cite this Article?

Manikandan, T., Sivashankaran, A., Kumar, C.S., and Kanagaraj, T. (2014).Lung Function Assessment For Asthma Treatment By Interfacing Of Sensors With Android App. i-manager’s Journal on Computer Science, 1(4), 16-21. https://doi.org/10.26634/jcom.1.4.2714

References

[1]. M. Masoli, D. Fabian, S. Holt, R. Beasley, and G. Program (2004), “The global burden of asthma: Executive summary of the GINA dissemination committee Report,” Allergy, Vol. 59, No. 5, pp.469–478.
[2]. “National asthma education and prevention program – Expert panel report 3 (EPR-3): Guidelines for the diagnosis and management of asthma – Summary report 2007,” Journal. Allergy and Clinical Immunology, Vol. 120, pp. S94– S138.
[3]. E. R. McFadden (2003), “Acute severe asthma,” Amer. Journal. Respiratory and Critical Care Med., Vol. 168, No. 7, pp. 740–759.
[4]. J. M. I. Garcia and P. Gonzalezsantos (1995), “Athma self-management education-program by home monitoring of peak expiratory flow,” Amer. J. Respiratory and Critical Care Med., Vol. 151, No. 2, pp. 353–359.
[5]. M. R. Miller, S. A. Dickinson, and D. J. Hitchings (1992), “The accuracy of portable peak flow meters,” Thorax, Vol. 47, No. 11, pp. 904–909.
[6]. C. Tantucci, A. Duguet, P. Giampiccolo, T. Similowski, M. Zelter, and J. P. Derenne (2002), “The best peak expiratory flow is flow-limited and effort-independent in normal subjects,” Amer. Journal. Respiratory and Critical Care Med., Vol. 165, No. 9, pp. 1304–1308.
[7]. P. G. Gibson, H. Powell, J. Coughlan, A. J. Wilson, M. Abramson, P. Haywood, A. Bauman, M. J. Hensley, and E. H. Walters (2009), “Self-management education and regular practitioner review for adults with asthma,” Cochrane Library 2009; Cochrane Database of Systematic Reviews, No. 3, pp. 1–81.
[8]. M. Molina, W. Zhao, S. Sankaran, M. Schivo, N. Kenyon, and C. Davis (2008), “Design-of- experiment optimization of exhaled breath con- densate analysis using a miniature differential mobility spectrometer (DMS),” Analytica Chimica Acta, Vol. 628, pp. 155–161.
[9]. M. Folke, L. Cernerud, M. Ekström, and B. Hök (2003), “Critical review of non-invasive respiratory monitoring in medical care,” Med. Biol. Eng. Comput., Vol. 41, pp. 377–383.
[10]. E. Traversa (1995), “Ceramics sensors for humidity detection: The state-of-the-art and future developments,” Sens. Actuat. B, Vol. 23,pp. 135–156.
[11]. A. Tetelin and C. Pellet (2006), “Modeling and optimization of a fast response capacitive humidity sensor,” IEEE Journal. Sens., Vol. 6, pp. 714–720.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.