Certain Investigations On Soft Computing Approach For Early Detection Of Diabetic Retinopathy

D.Gowthami*, R.Jayanthi**
* PG Scholar, Department of ECE, Nandha College of Technology, Erode.
** Professor, Department of ECE, Nandha College of Technology, Erode.
Periodicity:May - July'2013
DOI : https://doi.org/10.26634/jic.1.3.2354

Abstract

Diabetic retinopathy remains the leading cause of severe vision loss and blindness in the developed world, in spite of recognized ocular treatments that are successful at reducing the rate of vision impairment. Retinal photography appears a promising method to perform screening in such a setting utilizing new 45 degrees + retinal cameras that do not require pupil dilation and can be operated by a trained, non ophthalmic technician. Certain developments may make the photography more successful including the conversion to electronic chip camera sensors that allow each picture as it is taken to be immediately projected onto a monitor for evaluation and assessment. Utilizing a non mydriatic camera, studies of single-field photography through a dilated pupil have demonstrated superior or equal sensitivity to funds examination by an ophthalmologist in a number of studies. However, photography without pupil dilation, especially in the older age group may result in poor-quality photographs owing to intense bilateral pupil constriction after the first images and also due to the presence of cataracts. Computer analysis of the retinal images allows extraction of quantitative data, not only of the diabetic lesions but also of vascular changes that, up until now, have been impossible by human grading and potentially allows a much more detailed and quantitative evaluation of the progression of retinopathy over time. When success of image processing algorithms is demonstrated for a large number of images taken under screening conditions, the benefits of retinal photography and image processing to provide timely, reliable, quantitative and cost-effective results, will make this the preferred method over physician examination or human grader evaluation of the images.

Keywords

Biomedical Image Processing, Image Classification, Pattern Recognition, Medical Decision-Making, Diabetic Retinopathy

How to Cite this Article?

Gowthami, D., and Jayanthi, R. (2013). Certain Investigations On Soft Computing Approach For Early Detection Of Diabetic Retinopathy. i-manager’s Journal on Instrumentation and Control Engineering, 1(3), 31-39. https://doi.org/10.26634/jic.1.3.2354

References

[1]. Early Treatment Diabetic Retinopathy Study Research Group. (1991). “Early photocoagulation for diabetic retinopathy,” Ophthalmology, Vol. 98, pp. 766–85.
[2]. L.Vincent. (1993). “Morphological grayscale reconstruction in image analysis: Applications and efficient algorithms,” IEEE Trans. Image Process., Vol. 2, pp. 176–201, Apr. 1993.
[3]. T. Spencer., J.A. Olson,K.C.McHardy.,P .F.Sharp., & J. V.Forrester. (1996). “An image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus,” Comput. Biomed. Res., Vol. 29, pp. 284–302.
[4]. M. J. Cree., J. A. Olson., K. C. McHardy., P. F. Sharp, & J. V. Forrester. (1997). “A fully automated comparative micro aneurysm digital detection system,” Eye, Vol. 11, pp. 622–628.
[5]. A. Mendonca., A. Campilho., & J. Nunes. (1999). “Automatic segmentation of microaneurysms in retinal angiograms of diabetic patients,” in Proc. Int. Conf. Image Anal. Process., pp. 728–733.
[6]. L. Gagnon., M. Lalonde., M. Beaulieu., & M. C. Boucher. (2001). “Procedure to detect anatomical structures in optical fundus images,” in Proc. SPIE Med. Imag.: Image Process.,Vol. 4322, pp. 1218–1225.
[7]. F. Zana., & J. C. Klein (2001). “Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation,” IEEE Trans. Image Process., Vol. 10, No. 7, pp. 1010–1019.
[8]. K. H. Jarman., D. S. Daly., K. K. Anderson., & K. L. Wahl.(2003). “A new approach to automated peak detection,” Chemometr. Intell. Lab., Vol. 69, pp. 61–76.
[9]. M. Niemeijer., J. Staal., M. D. Abramoff., M. A. Suttorp-Schulten., & B. van Ginneken. (2005). “Automatic detection of red lesions in digital color fundus photographs,” IEEE Trans. Med. Imag., Vol. 24, No. 5, pp. 584–592.
[10]. A. D. Fleming., S. Philip., & K. A. Goatman. (2006). “Automated micro aneurysm detection using local contrast normalization and local vessel detection,” IEEE Trans. Med. Imag., Vol. 25, No. 9, pp. 1223–1232.
[11]. T. Walter., P. Massin., A. Arginay., R. Ordonez., C. Jeulin., & J. C. Klein. (2007). “Automatic detection of microaneurysms in color fundus images,” Med. Image Anal., Vol. 11, pp. 555–566.
[12]. F. Zana, & J. C. Klein (2001). “Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation,” IEEE Trans. Image Process., Vol. 10, No. 7, pp. 1010–1019, Jul. 2001.
[13]. M. Niemeijer., J. Staal., M. D. Abramoff., M. A. Suttorp-Schulten., & B. van Ginneken. (2005). “Automatic detection of red lesions in digital color fundus photographs,” IEEE Trans. Med. Imag., Vol. 24, No. 5, pp. 584–592.
[14]. P. J. Kertes., & T. M. Johnson, Eds. (2007). “Evidence Based Eye Care”. Philadelphia, PA: Lippincott Williams & Wilkins.
[15]. G. Quellec., M. Lamard., P. Josselin., G. Cazuguel., B. Cochener., & C.Roux. (2008). “Optimal wavelet transform for the detection of microaneurysms in retina photographs,” IEEE Trans. Med. Imag., Vol. 27, No. 9, pp.1230–1241, Sep. 2008.
[16]. A. Mizutani, C. Muramatsu, Y. Hatanaka, S. Suemori, T. Hara, and H. Fujita (2009). “Automated microaneurysm detection method based on double ring filter in retinal fundus images,” in Proc. SPIE Med. Imag. Comput.-Aided Diagnosis, 2009, Vol. 72601N.
[17]. B. Zhang., X. Wu., J. You., Q. Li., & F. Karray. (2010). “Detection of microaneurysms using multi-scale correlation coefficients,” Pattern Recognit., Vol. 43, No. 6, pp. 2237–2248.
[18]. K. Ram., G. D. Joshi., & J. Sivaswamy. (2011). “A successive clutter-rejection-based approach for early detection of diabetic retinopathy,” IEEE Trans. Biomed. Eng., Vol. 58, No. 3, pp. 664–673.
[19]. B. Antal., & A. Hajdu. (2012). “An ensemble-based system for microaneurysmdetection and diabetic retinopathy grading,” IEEE Trans. Biomed. Eng., Vol. 59, No. 6, pp. 1720–1726, Jun. 2012.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Online 200 35 35 200 15
Pdf 35 35 200 20
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.