A Review on Control strategies for LFC in Deregulated Scenario

T. Anilkumar*, N. Venkata ramana**
* Associate Professor, EEE Department, ACE Engineering College, Ghatkesar, Hyderabad, AP, India.
** Professor and Head of Deportment, EEE Department, JNTU Mantini, AP, India.
Periodicity:December - February'2013
DOI : https://doi.org/10.26634/jcir.1.1.2197

Abstract

In power system studies, Load frequency control is an important issue to supply sufficient and reliable electric power with good quality. The main objective of LFC is to maintain load frequency and tie-line power flow within permissible limits by adjusting megawatt output of LFC generators, so as to accommodate fluctuating load demands. This paper presents a brief review of different control techniques to researchers on design of LFC controllers in deregulated environment. The overview of different control strategies are explained in brief, such as Classical and Modern feedback controllers, Adaptive, Intelligent and Robust control strategies along with their relative advantages and disadvantages. Finally, incorporating Facts devices and Energy storage devices in the investigation of LFC problem have also been discussed.

Keywords

LFC, Deregulated power system, Robust Control, Intelligent Controller, Adaptive Control, Ancillary service

How to Cite this Article?

Kumar, T. A., and Ramana, N., (2013). A Review On Control Strategies For LFC In Deregulated Scenario. i-manager’s Journal on Circuits and Systems, 1(1), 27-36. https://doi.org/10.26634/jcir.1.1.2197

References

[1]. Vaibhav Donde, M., Pai, A., & Hiskens. (2001). Simulation and Optimization in an AGC System after Deregulation, IEEE Transactions on power systems, Vol. 16, No.3.
[2]. Liu, F., Song Y. H., J. Ma., S. Mei., & Q. Lu. (2003). Optimal load-frequency control in restructured power systems, Generation, Transmission and Distribution, IEEE Proceedings, 2003. Vol. 150.
[3]. Sadeh, J., & Rakhshani, E. (2008). Multi-area load frequency control in a deregulated power system using optimal output feedback method, Electricity Market, 2008. 5th International Conference on European.
[4]. Sadeh, J., & Rakhshani, E. (2008). Simulation of two-area AGC system in a competitive environment using reduced-order observer method, Electricity Market, EEM. 5th International Conference on European.
[5]. Sadeh, J., & Rakhshani, E. (2009). A Reduced- Order Estimator with Prescribed Degree of Stability for Two-Area LFC System in a Deregulated Environment, Power Systems Conference and Exposition, PSCE '09,IEEE/PES.
[6]. Sadeh, J., & Rakhshani, E. (2010). Practical viewpoints on load frequency control problem in a deregulated power system, Energy Conversion and Management, Volume 51, Issue 6, Pages 1148–1156.
[7]. Barjeev, Tyagi, & Srivastava, S.C. (2003). A fuzzy logic based load frequency controller in a competitive electricity environment, Power Engineering Society General Meeting, IEEE, Volume: 2.
[8]. Demiroren, A., & Zeynelgil, H. L. (2007). GA application to optimization of AGC in three-area power system after deregulation, Elsevier, International Journal of Electrical Power & Energy Systems, Volume 29, Issue 3, Pages 230–240.
[9]. Ali, E. S., & Abd Elazim, S. M. (2011). Bacteria foraging optimization algorithm based load requency controller for interconnected power system, Elsevier, International Journal of Electrical Power & Energy Systems. Volume 33, Issue 3, Pages 633–638.
[10]. Abedinia, O., Naderi, M. S., & Ghasemi. (2011). A Robust LFC in deregulated environment: Fuzzy PID using HBMO, 10th International Conference on Environment and Electrical Engineering (EEEIC), Publication Page(s): 1 – 4.
[11]. Abedinia, O., Amjady, N., & Naderi, M. S. (2012). Multi-stage Fuzzy PID Load Frequency Control via SPHBMO in deregulated environment, 11th International Conference on Environment and Electrical Engineering (EEEIC), Page(s): 473 – 478.
[12]. Debbarma. S., & Saikia. L. C. (2012). Bacterial foraging based FOPID controller in AGC of an interconnected two-area reheat thermal system under deregulated environment, Advances in Engineering, International Conference on Science and Management (ICAESM), Publication, Page(s): 303 – 308.
[13]. Le-Ren Chang-Chien Chien-Sheng Lo Ko- Shien Lee. (2005). Application of ANN-SCE Model on the Evaluation of Automatic Generation Control Performance, Proceeding (465) Energy and Power Systems.
[14]. Bevrani, Hassan., Hiyama, Takashi., Mitani, Yasunori., Tsuji, Kiichiro., Teshnehlab., & Mohammad. (2006). Load-frequency regulation under a bilateral LFC scheme using flexible neural networks. Engineering Intelligent Systems, 14(2), pp. 109-117.
[15]. Hosseini, S. H., & Etemadi, A. H. (2008). Adaptive neuro-fuzzy inference system based automatic generation control, Elsevier, Electric Power Systems Research 78 1230–1239.
[16]. Sabahi, K., Narimani, E., & Faramarzi, A. (2010). Dynamic neural network for AGC in restructure power system, IEEE International Conference on Power and Energy (PECon), Page(s): 594- 599.
[17]. Sathans, S., & Swarup, A. (2011). Intelligent Load Frequency Control of Two-Area Interconnected Power System and Comparative Analysis. 2011 International Conference on Communication Systems and Network Technologies (CSNT), Page(s): 360 – 365.
[18]. Srinivasa Rao, C. (2012). Adaptive Neuro Fuzzy based Load Frequency Control of multi area system under open market scenario. Science and Management (ICAESM), International Conference on Advances in Engineering, Page(s): 5 – 10.
[19]. Ali, Feliachi. (1996). On Load Frequency Control in a Deregulated Environment, Proceedings of the IEEE International Conference on Control Applications Dearborn, MI September 15-18; 437-441
[20]. Ali, Feliachi. (1997). Reduced H? Load Frequency Controller in a Deregulated Electric Power System Environment, Proceedings of the 36th Conference on Decision & Control San Diego, California USA*.
[21]. Bevrani, H. (1999). Robust load frequency controller in a deregulated environment: a ?- synthesis approach. Control Applications. Proceedings of the IEEE International Conference on control applications, Page(s): 616-621 Vol. 1.
[22]. Bevrani, H., Mitani, Y., & Tsuji, K. (2004). Robust decentralized AGC in a restructured power system, Elsevier, Energy Conversion and Management 45, 2297–2312.
[23]. Bevrani, H., Mitani, Y., Tsuji, K. (2004). Pibased multi-objective load-frequency control in a restructured power system, SICE Annual Conference, Volume: 2 Page(s): 1745 – 1750.
[24]. Bevrani, H., Mitani, Y., & Tsuji, K., (2004). Robust Decentralized LFC Design In a Deregulated Environment, IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies (DRPT2004), Hong Kong.
[25]. Shayeghi, H., Shayanfar, H. A., & Malik. O. P. (2007). Robust decentralized neural networks based LFC in a deregulated power system, Elsevier, Electric Power Systems Research, Volume 77, Issues 3–4, Pages 241– 251.
[26]. Rezvantalab, J., Kazemi, M. H., & Seddigh, A.K. (2009). Multi-area robust decentralized Load Frequency Controller design in a restructured power system using Quantitative Feedback Theory, Electric Power and Energy Conversion Systems, EPECS '09. International Conference on Publication, Page(s): 1 – 6.
[27]. Ngamroo, I., Mitani, Y., & Tsuji, K., (1999). Robust Load frequency control by solid-state phase shifter based on H? control design, Power Engineering Society Winter Meeting, IEEE, Page(s): 725 - 730, Vol.1.
[28]. Kazemi, A., & Andami, H. (2004). FACTS devices in deregulated electric power systems: a review. Proceedings of the IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies, Page(s): 337 - 342, Vol.1.
[29]. Sterpu, S., Bésanger, Y., & Hadj Saïd, N. (2005). Ancillary Services Performance Control in Deregulated Power Systems. Power Engineering Society General Meeting, IEEE, Page(s): 3048- 3054 Vol. 3.
[30]. Shayeghia, H., Jalilib, A., & Shayanfarc, H. A. (2008). A robust mixed H2/H? based LFC of a eregulated power system including SMES. Elsevier, Energy Conversion and Management, Volume 49, Issue 10, Pages 2656–2668.
[31]. Shayeghi, H., Shayanfar, H. A., & Jalili, A., (2009). LFC Design of a Deregulated Power System with TCPS Using PSO. World Academy of Science, Engineering and Technology.
[32]. Praghnesh, Bhatt., Ranjit, Roy., Ghoshal, S. P. (2010). Coordinated Control of SSSC and SMES in Competitive Electricity Market for Load Frequency Control. IEEE 11th International Conference on Probabilistic Methods Applied to Power Systems (PMAPS), 14-17, Page(s): 42- 47.
[33]. Kumar. T. A., Krishna. V. S., & Ramana. N. V. (2011). Improvement of dynamic performance of three area thermal system under deregulated environment using AC tie-line parallel with HVDC link, International Conference on Power and Energy Systems (ICPS), 22-24, Page(s): 1 – 6.
[34]. Ibraheem, Prabhat Kumar, Naimul Hasana & Yadav Singh, (2012). Optimal Automatic Generation Control of Interconnected Power System with Asynchronous Tie lines under Deregulated Environment, Electric Power Components and Systems, Volume 40, Issue 10.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.