Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer

S.Padmini*, Subransu Sekhar Dash**, S. Chandrasekhar***, Priyanka Vedula****
* Assistant Professor, SRM University.
** Professor and Head, Department of EEE, SRM University, Shruti.
***-**** B. Tech Student, SRM University.
Periodicity:December - February'2013
DOI : https://doi.org/10.26634/jcir.1.1.2194

Abstract

Advances Differential prot ecti on system is us e d t o protect most of the power transformers in power systems. The protection system is based on the differential currents/voltages of the primary an d secondary of the transformers under fault conditions and under normal operating conditions. The inrus currents or the magnetizing currents are generated in the transformer when it is switched on to the transmission system or the external fault in the system is cleared. The inrush currents other than the fault currents may activate the differential protection system if suitable blocking scheme is not incorporated in the protection system of the power transformer. Therefore, identification of inrush current and the fault currents is the key to improve the security of the differential protection scheme. This paper proposes the development of a new algorithm to improve the differential protection performance by using fuzzy logic and Clarke's transform. The result obtained concludes an effective method to differentiate the different internal faults with accuracy as well as shows an improvement in the time taken to detect faults

Keywords

MATLAB, Clarke’s transform, internal faults, differential protection, magnetizing inrush, fuzzy logic, power transformer.

How to Cite this Article?

Padmini, S., Dash, S. S., Chandrasekhar, S. and Vedula, P. (2013). Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer. i-manager’s Journal on Circuits and Systems, 1(1), 10-15. https://doi.org/10.26634/jcir.1.1.2194

References

[1]. J.H. Harlow, Ed., Electric Power Transformer Engineering, and 2nd ed.Boca Raton, FL: CRC, 2007.
[2]. M. Sengül, B. Alboyaci, and H. B. Cetinkaya, “Case study of sympathetic interaction between transformers caused by inrush transients,”presented at the Int. Conf. Power Systems Transients, Montreal, QC, Canada, Jun. 19-23, 2005.
[3]. Protective Relaying: Theory and Applications, W. A. Elmore, Ed., 2nded. New York: Marcel Dekker, 2004.
[4]. A.G. Phadke and J.S. Thorp, “A new computer-based lux-restrainedcurrent-differential relay for power transformer protection,” IEEE Trans. Power App. Syst., Vol. PAS-102, No. 11, pp. 3624-3629, Nov.1983.
[5]. A. Wiszniewski and B. Kasztenny, “Fuzzy set approach to transformer differential relay,” in Proc. Developments in Power System Protection Conf., York, U.K., Jun. 1993, pp. 169-172.
[6]. M.-C. Shin, C.-W.Park, and J.-H. Kim, “Fuzzy logic-based relaying for large power transformer protection,” IEEE Trans. Power Del., Vol.18, No. 3, pp. 718-724, Jul. 2003.
[7]. S.H. Horowitz and A.G. Phadke, Power System Relaying, 2nd ed. New York: Wiley, 1992.
[8]. Z. Han, S. Liu, S. Gao, and Z. Bo, “Flow-through inrush and its effect on transformer differential protection,” in Proc. Inst. Eng. Technol.9th Int. Conf. Developments in Power System Protection, Mar. 17-20,2008, pp. 296-301.
[9] M. J. Heathcote, The J&P Transformer Book. Oxford, U.K.: Elsevier,2007.
[10]. E. Segatto and D. Coury, “A differential relay for power transformers using intelligent tools,” IEEE Trans. Power Syst., Vol. 21,No. 3.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.