Abstract

The common mode voltage (CMV) generated by multilevel inverters can be reduced. This paper presents a Spacevector pulse width modulation (SVPWM) approach for cascaded 3-level inverters to reduce common mode voltage. Conventional 3-level pulse width modulated (PWM) inverters are widely known for producing high-frequency commonmode voltages with high dv/dt. Motor shaft voltages and bearing currents can be caused by common mode voltages. In this work, to reduce common mode voltage, partial CMV elimination technique is used. In this method the redundant states of 3-level inverter having CMV less than or equal to Vdc/6 are only used and the redundant states having CMV greater than Vdc/6 are avoided by implementing SVPWM, where Vdc is the input DC voltage of inverter. A simulation of an SVM technique to reduce common mode voltage is implemented. Bearing voltages, bearing currents and total harmonic distortion (THD) are evaluated in the performance analysis. The results will prove the reduction of CMV with the proposed technique compared to conventional SVPWM.

Keywords

Common Mode Voltage (CMV), Bearing Currents, 3-Level Cascaded Inverter, Space Vector Pulse Width Modulation (SWPWM).

How to Cite this Article?

Swamy, R. L., and Somanatham, R. (2022). Reduction of Common Mode Voltage for Cascaded 3-Level Inverter using SVPWM. i-manager’s Journal on Electrical Engineering, 15(4), 1-11. https://doi.org/10.26634/jee.15.4.18626

References

[1]. Bose, B. K. (2020). Power Electronics and Motor Drives: Advances and Trends (2nd Ed.). Academic Press.
[2]. Busse, D., Erdman, J., Kerkman, R. J., Schlegel, D., & Skibinski, G. (1997). Bearing currents and their relationship to PWM drives. IEEE Transactions on Power Electronics, 12(2), 243-252. https://doi.org/10.1109/63.558735
[3]. Erdman, J. M., Kerkman, R. J., Schlegel, D. W., & Skibinski, G. L. (1996). Effect of PWM inverters on AC motor bearing currents and shaft voltages. IEEE transactions on Industry Applications, 32(2), 250-259. https://doi.org/10.1109/28.491472
[4]. Gupta, A. K., & Khambadkone, A. M. (2007). A space vector modulation scheme to reduce common mode voltage for cascaded multilevel inverters. IEEE Transactions on Power Electronics, 22(5), 1672-1681. https://doi.org/10.1109/TPEL.2007.904195
[5]. Holtz, J. (1992). Pulse width modulation-a survey. IEEE Transactions on Industrial Electronics, 39(5), 410-420. https://doi.org/10.1109/41.161472
[6]. Kim, H. J., Lee, H. D., & Sul, S. K. (2001). A new PWM strategy for common-mode voltage reduction in neutralpoint- clamped inverter- fed AC motor drives. IEEE Transactions on Industry Applications, 37(6), 1840-1845. https://doi.org/10.1109/28.968199
[7]. Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., ... & Leon, J. I. (2010). Recent advances and industrial applications of multilevel converters. IEEE Transactions on Industrial Electronics, 57(8), 2553-2580. https://doi.org/10.1109/TIE.2010.2049719
[8]. Loh, P. C., Holmes, D. G., Fukuta, Y., & Lipo, T. A. (2003). Reduced common-mode modulation strategies for cascaded multilevel inverters. IEEE Transactions on Industry Applications, 39(5), 1386-1395. https://doi.org/10.1109/TIA.2003.816547
[9]. Mohan, N., Undeland, T. M., & Robbins, W. P. (2003). Power Electronics: Converters, Applications, and Design. John Wiley & Sons.
[10]. Mütze, A., & Binder, A. (2005, May). Calculation of motor capacitances for prediction of discharge bearing currents in machines of inverter-based drive systems. In IEEE International Conference on Electric Machines and Drives, 2005. (pp. 264-270). IEEE. https://doi.org/10.1109/IEMDC.2005.195733
[11]. Rashid, M. H. (Ed.). (2017). Power Electronics Handbook. Butterworth-heinemann.
[12]. Rodríguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007). Multilevel voltage-source-converter topologies for industrial medium-voltage drives. IEEE Transactions on Industrial Electronics, 54(6), 2930-2945. https://doi.org/10.1109/TIE.2007.907044
[13]. Rodriguez, J., Lai, J. S., & Peng, F. Z. (2002). Multilevel inverters: A survey of topologies, controls, and applications. IEEE Transactions on Industrial Electronics, 49(4), 724-738. https://doi.org/10.1109/TIE.2002.801052
[14]. Wang, F. (2000). Motor shaft voltages and bearing currents and their reduction in multilevel medium-voltage PWM voltage-source-inverter drive applications. IEEE Transactions on Industry Applications, 36(5), 1336-1341. https://doi.org/10.1109/28.871282
[15]. Zhang, H., Von Jouanne, A., Dai, S., Wallace, A. K., & Wang, F. (2000). Multilevel inverter modulation schemes to eliminate common-mode voltages. IEEE Transactions on Industry Applications, 36(6), 1645-1653. https://doi.org/10.1109/28.887217
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Online 15 15

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.