th , 7th , and 11th harmonics were used to test the proposed Shunt Active Filter with improved PI controller resulting in harmonic content reduced to 1.89%.

">

Shunt Active Filter for Source Current Harmonics

Seema*, S. G. Ankaliki **
*-** Department of Electrical and Electronics Engineering, S.D.M. College of Engineering and Technology, Dharwad, Karnataka, India.
Periodicity:February - April'2020
DOI : https://doi.org/10.26634/jps.8.1.17464

Abstract

In this paper the synchronous reference frame PI-based control method for generating the reference signals for the Voltage Source Converter (VSC) of Shunt Active Filter (SAF) is presented. The method depends on the performance of the Proportional-Integral (PI) controller to achieve the best control performance of the SAF. Using reference frame transformation, reference signals were transformed from a - b - c stationery frame to 0 - d - q rotating frame. Using the PI controller, reference signals in 0 - d - q rotating frame were controlled to get the desired reference signals for the Pulse Width Modulation (PWM). Using MATLAB/SIMULINK simulation, the 5th , 7th , and 11th harmonics were used to test the proposed Shunt Active Filter with improved PI controller resulting in harmonic content reduced to 1.89%.

Keywords

Phase Locked Loop (PLL), Voltage Source Converter (VSC), Shunt Active Filter(SAF), Proportional Integral (PI), Pulse Width Modulation (PWM), MATLAB/Simulink.

How to Cite this Article?

Seema and Ankaliki, S. G. (2020). Shunt Active Filter for Source Current Harmonics. i-manager’s Journal on Power Systems Engineering, 8(1), 1-8. https://doi.org/10.26634/jps.8.1.17464

References

[1]. Akagi, H. (1996). New trends in active filters for power conditioning. IEEE Transactions on Industry Applications, 32(6), 1312-1322.
[2]. Anand, V., & Srivastava, S. K. (2012). Performance investigation of shunt active power filter using hysteresis current control method. International Journal of Engineering Research & Technology (IJERT), 1(4).
[3]. Atan, N. B., & Yunus, B. B. (2009, December). Evaluation of reference signal estimation techniques for the control of rd shunt active power filter. In 2009, 3 International Conference on Energy and Environment (ICEE) (pp. 290- 293). IEEE.
[4]. Bukka, S., Yunus, M., Hakim, M., Sanjeev, T. M., & Ankaliki, S. G. (2014). Performance analysis of three phase shunt hybrid active power filter. International Journal of Research in Engineering and Technology (IJRET), 3(3), 257- 263.
[5]. Kanjiya, P., Khadkikar, V., & Zeineldin, H. H. (2015). Optimal control of shunt active power filter to meet IEEE Std. 519 current harmonic constraints under non-ideal supply condition. IEEE Transactions on Industrial Electronics, 62(2), 724-734.
[6]. Mahajan, V., Agarwal, P., & Gupta, H. (2012). Simulation of shunt active power filter using instantaneous power theory. In 2012, IEEE Fifth Power India Conference, (pp. 1-5).
[7]. Mane, M., & Namboothiripad, M. K. (2017). Performance investigation of fractional pi controller in shunt active filter for a three phase four wire system. In International Conference on Nascent Technologies in Engineering (ICNTE).
[8]. Panchbhai, A., Parmar, S., & Prajapati, N. (2017). Shunt active filter for harmonic and reactive power compensation using p-q theory. In International Conference on Power and Embedded Drive Control (ICPEDC) (pp. 260-264).
[9]. Puhan, P. S., Ray, P. K., & Panda, G. (2017, February). Performance improvement of shunt active power filter with combined control technique. In 2017 International Conference on Emerging Trends and Innovation in ICT (ICEI) (pp. 56-61). IEEE.
[10]. Singh, B., Al-Haddad, K., & Chandra, A. (1999). A review of active filters for power quality improvement. IEEE Transactions on Industrial Electronics, 46(5), 960-971.
[11]. Soares, V., Verdelho, P., & Marques, G. D. (2000). An instantaneous active and reactive current component method for active filters. IEEE Transactions on Power Electronics, 15(4), 660-669.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Online 15 15

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.