A New Design for Low Rating Three Phase Squirrel Cage Induction Motor with Improved Performance Operating Under Rated Voltage-A Design Consideration for Rural Areas

Raj Kumar Saini*, Devender Kumar Saini**, Rajeev Gupta***, Piush Verma****
* Shoolini University, Solan, Himachal Pradesh, India. **-*** University of Petroleum and Energy Study, Dehradun, Uttarakhand, India. **** Bahra University, Vaknaghat, Solan,Himachal Prasesh, India.
Periodicity:October - December'2019
DOI : https://doi.org/10.26634/jee.13.2.16219

Abstract

This research article deals with modified and ideal plan parameters of 1HP three phase squirrel cage induction motor working under rated voltages. The simulated results are calculated with the assistance of JMAG Express (an electrical machine design software) under rated voltage. Based on the simulated results of stator and rotor design of 1 HP three phase squirrel cage induction motor is casted in the industry. The experimental results of a new 1 HP motor are compared with experimental results of standard motor of the same rating which was designed at rated voltage. The after effects of new planned motor was better when compared with old one. These types of low rating induction motors can be used in the villages for agribusiness and domestic purposes to show signs of improvement effectiveness.

Keywords

Induction Motor, Under Rated Voltage, Torque, Efficiency

How to Cite this Article?

Saini, R. K., Saini, D. K., Gupta, R., & Verma, P. (2019). A New Design for Low Rating Three Phase Squirrel Cage Induction Motor with Improved Performance Operating Under Rated Voltage-A Design Consideration for Rural Areas. i-manager’s Journal on Electrical Engineering, 13(2), 11-17. https://doi.org/10.26634/jee.13.2.16219

References

[1]. ANSI C84.1- 2011 (n.d). American National Standard for Electric Power Systems and Equipment - Voltage Ratings. (60 Hertz). Retrieved from http://www.powerqualityworld. com/2011/04/ansi-c84-1-voltage-ratings-60-hertz. html
[2]. Anwari, M., & Hiendro, A. (2010). New unbalance factor for estimating performance of a three-phase induction motor with under and over voltage unbalance. IEEE Transactions on Energy Conversion, 25(3), 619-625. https://doi.org/10.1109/TEC.2010.2051548
[3]. Bhushan, B., & Singh, M. (2011). Adaptive control of DC motor using bacterial foraging algorithm. Applied Soft Computing, 11(8), 4913-4920. https://doi.org/10.1016/j. asoc.2011.06.008
[4]. Bollen, M. H. (2000). Understanding power quality problems. In Voltage Sags and Interruptions. IEEE press.
[5]. EN 50160 (2010). Voltage characteristics of electricity supplied by public distribution network. Retrieved from https://infostore.saiglobal.com/preview/98699522296.pdf ?sku=859794_saig_nsai_nsai_2045468
[6]. EN-ICE 61000-2-4 (2002). Electromagnetic Compatibility (EMC) – Part 2–4: Environment compatibility levels in industrial plants for low-frequency conducted disturbances. Retrieved from https://webstore.iec.ch/ publication/4135
[7]. Faiz, J., & Ebrahimpour, H. (2007). Precise derating of three phase induction motors with unbalanced voltages. Energy Conversion and Management, 48(9), 2579-2586. https://doi.org/10.1016/j.enconman.2007.03.023
[8]. Gnaci, P. (2008). Windings temperature and loss of life of an induction machine under voltage unbalance combined with over-or undervoltages. IEEE Transactions on Energy Conversion, 23(2), 363-371. https://doi.org/10. 1109/TEC.2008.918596
[9]. Gnacinski, P. (2008). Effect of unbalanced voltage on windings temperature, operational life and load carrying capacity of induction machine. Energy Conversion and Management, 49(4), 761-770. https://doi.org/10.1016/j. enconman.2007.07.033
[10]. Gnacinski, P. (2009). Derating of an induction machine under voltage unbalance combined with over or undervoltages. Energy Conversion and Management, 50(4), 1101-1107. https://doi.org/10.1016/j.enconman. 2008.12.006
[11]. Gnaciński, P. (2009). Effect of power quality on windings temperature of marine induction motors: Part I: Machine model. Energy Conversion and Management, 50(10), 2463-2476. https://doi.org/10.1016/j.enconman. 2009.05.011
[12]. Gnacinski, P. (2014). Thermal loss of life and loadcarrying capacity of marine induction motors. Energy Conversion and Management , 78, 574-583. https://doi.org/10.1016/j.enconman.2013.11.023
[13]. IEC Std. 60034-1 (2004). Rotating electrical machines. Part 1: Rating and performance. Retrieved from https://webstore.iec.ch/publication/12285
[14]. Kumar, S. R., Kumar, S. D., Rajeev, G., & Piush, V. (2016). Optimized design of three phase squirrel cage induction motor based on maximum efficiency operating under the rated voltage–based on software platform. Indian Journal of Science and Technology, 9, 21. https://doi.org/10.17485/ijst/2016/v9i21/92002
[15]. Lee, S. J., Kim, J. M., An, D. K., & Hong, J. P. (2014). Equivalent circuit considering the harmonics of core loss in the squirrel-cage induction motor for electrical power steering application. IEEE Transactions on Magnetics, 50(11), 1-4. https://doi.org/10.1109/TMAG.2014.2329316
[16]. Mangaraj, B. B., Misra, I. S., & Sanyal, S. K. (2011). Application of bacteria foraging algorithm for the design optimization of multi-objective Yagi-Uda array. International Journal of RF and Microwave Computer- Aided Engineering, 21(1), 25-35. https://doi.org/10.1002/ mmce.20483
[17]. Mendes, A. M. S., Quispe, E. C., Fernández, X. L., & Cardoso, A. M. (2010, September). Influence of the positive sequence voltage on the temperature of threephase induction motors. In XIX International Conference on Electrical Machines-ICEM 2010 (pp. 1-6). IEEE. https://doi. org/10.1109/ICELMACH.2010.5608011
[18]. Muñoz-Galeano, N., Alfonso-Gil, J. C., Orts-Grau, S., Segui-Chilet, S., & Gimeno-Sales, F. J. (2015). Instantaneous approach to IEEE Std. 1459 power terms and quality indices. Electric Power Systems Research, 125, 228- 234. https://doi.org/10.1016/j.epsr.2015.04.012
[19]. NEMA., MG.1-2009 (n.d). Motors and generators. Retrieved from https://webstore.ansi.org/standards/nema/ nemamg2009revision2010
[20]. Quispe, E. C., López-Fernández, X. M., Mendes, A. M. S., Cardoso, A. M., & Palacios, J. A. (2011, May). Experimental study of the effect of positive sequence voltage on the derating of induction motors under voltage unbalance. In 2011 IEEE International Electric Machines and Drives Conference (IEMDC) (pp. 908-912). IEEE. https://doi.org/10.1109/IEMDC.2011.5994936
[21]. Saini, R. K., Saini, D. K., Gupta, R., Dwivedi, R. P., & Verma, P. (2018). Design, analysis, and assessment of efficiency of three-phase squirrel-cage induction motors operating under the rated voltage: A design consideration for rural areas. In Intelligent Communication, Control and Devices (pp. 13-21). Singapore: Springer, https://doi.org/10. 1007/978-981-10-5903-2_2
[22]. Santos, V. S., Felipe, P. R. V., Sarduy, J. R. G., Lemozy, N. A., Jurado, A., & Quispe, E. C. (2014). Procedure for determining induction motor efficiency working under distorted grid voltages. IEEE Transactions on Energy Conversion, 30(1), 331-339. https://doi.org/10.1109/TEC. 2014.2335994
[23]. Subramanian, S., & Padma, S. (2011). Bacterial foraging algorithm based multiobjective optimal design of single phase transformer. Journal of Computer Science and Engineering, 6, 1-6.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Online 15 15

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.