Correction of Power Factor and Balancing of 3 Phase Unbalanced Load

Shekhappa G. Ankaliki *, Akshay Hegde**, Sanjeeth Amminabhavi ***
* Professor & Head, Department of Electrical & Electronics Engineering, SDM College of Engineering and Technology, Dharwad, India.
**_*** PG Scholar, Department of Electrical & Electronics Engineering,SDM College of Engineering and Technology, Dharwad, India.
Periodicity:August - October'2018
DOI : https://doi.org/10.26634/jps.6.3.15482

Abstract

This paper presents correction of power factor and balancing of three phase unbalanced load. The analytical way of correction of power factor and balancing the three phase unbalanced delta connected load is carried out. The analytical results are compared with Matlab simulation results. Simulated results reveal that after correction of power factor and balancing of three phase unbalanced load, all three supply currents are in phase with their respective phase voltages and equal in magnitude resulting in a balanced load on supply system

Keywords

Load Balancing, Power Factor Correction, Reactive Power Shunt Compensation, MATLAB Simulation

How to Cite this Article?

Ankaliki, G. S., Hegde, A., and Amminabhavi, S. (2018). Power Factor Correction and Balancing of Unbalanced Load. i-manager’s Journal on Power Systems Engineering, 6(3), 1-6. https://doi.org/10.26634/jps.6.3.15482

References

[1]. Czarnecki, L. S., Hsu, S. M., & Chen, G. (1995). Adaptive balancing compensator. IEEE Transactions on Power Delivery, 10(3), 1663-1669.
[2]. Ghosh, A., & Joshi, A. (2000). A new approach to load balancing and power factor correction in power distribution system. IEEE Transactions on Power Delivery, 15(1), 417-422.
[3]. Gueth, G., Enstedt, P., Rey, A., & Menzies, R. W. (1987). Individual phase control of a static compensator for load compensation and voltage balancing and regulation. IEEE Transactions on Power Systems, 2(4), 898-905.
[4]. Husain, Z., Singh, R. K., & Tiwari, S. N. (2010, June). Balancing of unbalanced load and power factor correction in multi-phase (4-phase) load circuits using DSTATCOM. In Proceedings of the World Congress on Engineering (Vol. 2).
[5]. Mayordomo, J. G., Izzeddine, M., & Asensi, R. (2002). Load and voltage balancing in harmonic power flows by means of static VAr compensators. IEEE Transactions on Power Delivery, 17(3), 761-769.
[6]. Miller, T. J. E. (2010). Reactive Power Control in Electrical Systems. Wiley India.
[7]. Otto, R. A., Putman, T. H., & Gyugyi, L. (1978). Principles and applications of static, thyristor-controlled shunt compensators. IEEE Transactions on Power Apparatus and Systems, PAS-97(5), 1935-1945.
[8]. Pan, Z., Peng, F. Z., & Wang, S. (2005). Power factor correction using a series active filter. IEEE Transactions on Power Electronics, 20(1), 148-153.
[9]. Quintela, F. R., Arévalo, J. M. G., Redondo, R. C., & Melchor, N. R. (2011). Four-wire three-phase load balancing with Static VAr Compensators. International Journal of Electrical Power & Energy Systems, 33(3), 562- 568.
[10]. Said, I. K., & Pirouti, M. (2009). Neural network-based load balancing and reactive power control by Static VAR compensator. International Journal of Computer and Electrical Engineering, 1(1), 25-31.
[11]. Steinmetz, C. P. (1917). Theory and Calculation of Electrical Apparatus. New York, USA: McGraw Hill.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.