TM based simulation is carried out for the MFDC with 220 KVA welding transformer in resistance spot welding systems.
">This paper is an attempt to accomplish a performance analysis of the different control techniques on current spike reduction by means of magnetization level control in the primary winding on the medium frequency transformer based DC spot welding system. Current Spike reduction is an important factor to be considered while spot welding systems are concerned. The current control technique is a piecewise linear control technique that is inspired from the DC-DC converter control algorithms to register a novel current spike reduction method in the MFDC spot welding applications. The different controllers that were used for the current spike reduction by means of magnetization level control of the overall applications involve the hysteresis controller, Proportional Integral (PI) controller. Care is taken such that the current control technique would maintain a reduced current spike in the primary current of the transformer while it reduces the Total Harmonic Distortion. In this research, intelligent control system is introduced by using Adaptive Neuro Fuzzy Inference System (ANFIS). The performance of ANFIS controller is presented considering the parameters, percentage of current spike reduction, and THD. It is proved that current spikes are controlled successfully and has less THD than the above mentioned conventional controllers. Matlab/SimulinkTM based simulation is carried out for the MFDC with 220 KVA welding transformer in resistance spot welding systems.