Abstract

Compressive technique is also known as compressive sampling in signal processing domain and its recent algorithm can be integrated into the MRI reconstruction pipeline for acquiring the complete MR data. The proposed work is based on the recursive iterative adaptive filtering technique based on every injection of random noise in the unobserved portion of the spectrum. The proposed volumetric filter attenuates the noise and relevant features from the incomplete k-space measurements which is required for the clinical practice. The proposed algorithm is based on stochastic approximation method with regularization parameter enabled by a spatial adaptive block-wise volumetric filter. The effectiveness of the proposed reconstruction algorithm is compared with CT reconstruction algorithm radon inversion from sparse projections, spiral, radial, and limited angle tomography. From the reconstruction algorithm it is observed that it achieves exact reconstruction from phantom data even at small projections. The accuracy of this method is to compete with the compressed sensing field. The proposed algorithm is tested on different sampling trajectories, especially on non- Cartesian data and reconstruction of volumetric phantom data with non-zero phase from noisy and incomplete Fourierdomain (k-space) measurements. Experimental results demonstrate that its performance is evaluated by PSNR, SSIM, and execution time.

Keywords

Volumetric Filtering, Compressed Sensing, Cardiac Imaging, Sampling Trajectories

How to Cite this Article?

Anjanappa, C. and Sheshadri, H.S. (2017). Iterative Reconstruction Algorithm to Remove Noise and Artifacts in MRI. i-manager’s Journal on Image Processing, 4(3), 8-15. https://doi.org/10.26634/jip.4.3.13918

References

[1]. Fessler, J. A., & Noll, D. C. (2004). Iterative image reconstruction in MRI with separate magnitude and phase regularization. In Biomedical Imaging: Nano to Macro, 2004. IEEE International Symposium on (pp. 209- 212). IEEE.
[2]. Funai, A. K., Fessler, J. A., Yeo, D. T., Olafsson, V. T., & Noll, D. C. (2008). Regularized field map estimation in MRI. IEEE Transactions on Medical Imaging, 27(10), 1484-1494.
[3]. Gach, H. M., Tanase, C., & Boada, F. (2008). 2D & 3D Shepp-Logan phantom standards for MRI. In Systems th Engineering, 2008. ICSENG'08. 19 International Conference on (pp. 521-526). IEEE.
[4]. Haacke, E. M., Brown, R. W., Thompson, M. R., & Venkatesan, R. (1999). Magnetic Resonance Imaging: Physical Principles and Sequence Design (Vol. 82). New York:: Wiley-Liss.
[5]. Liang, Z. P., & Lauterbur, P. C. (2000). Principles of Magnetic Resonance Imaging: A Signal Processing Perspective. SPIE Optical Engineering Press.
[6]. Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008). Compressed sensing MRI. IEEE Signal Processing Magazine, 25(2), 72-82.
[7]. Milanfar, P. (2013). A tour of modern image filtering: New insights and methods, both practical and theoretical. IEEE Signal Processing Magazine, 30(1), 106-128.
[8]. Schabel, M. (2006). 3D Shepp-Logan Phantom. MATLAB Central File Exchange, 1-35.
[9]. Shepp, L. A., & Logan, B. F. (1974). The Fourier reconstruction of a head section. IEEE Transactions on Nuclear Science, 21(3), 21-43.
[10]. Vincent, R. (2006). Brain web: Simulated brain database. Retrieved from: http://mouldy.bic.mni. mcgill.ca/brainweb/
[11].Wright, G. (1997). Magnetic resonance imaging. IEEE Signal Processing Magazine, 14(1), 56-66.
[12]. Zhao, F., Noll, D. C., Nielsen, J. F., & Fessler, J. A. (2012). Separate magnitude and phase regularization via compressed sensing. IEEE Transactions on Medical Imaging, 31(9), 1713-1723.
[13]. Zibetti, M. V., and De Pierro, A. R. (2010, April). Separate magnitude and phase regularization in MRI with incomplete data: Preliminary results. In Biomedical Imaging: From Nano to Macro, 2010 IEEE International Symposium on (pp. 736-739). IEEE.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.