Wavelet-Fuzzy Based Digital Protection Scheme Of Four terminal Transmission System In The Presence Of UPFC

J. Uday Bhaskar*, G.Ravi kumar**, S. S. Tulasi Ram***
* Associate Professor, Department of Electrical and Electronics Engineering, DMSSVH College of Engineering, A.P., India.
** Professor, Department of Electrical and Electronics Engineering, Bapatla Engineerng College, A.P.,, India.
*** Professor, Department of Electrical and Electronics Engineering, University College of Engineering, JNTUH, Hyderabad, India.
Periodicity:January - March'2017
DOI : https://doi.org/10.26634/jee.10.3.13411

Abstract

The difficulties in obtaining the Right-of-Way have led to the development of multi-terminal transmission systems and these transmission systems are more vulnerable to faults and required to be cleared immediately as soon as they do occur for minimizing the power system disturbances and for efficient transmission. This paper aims in the systematic approach for fault detection, classification, faulty terminal identification, and fault location estimation of a four-terminal transmission system compensated with Unified Power Flow Controller (UPFC) based on frequency domain approach employing wavelet multi resolution analysis with the variations in fault inception angle, fault distance, and fault impedance by extracting the fault indices of current signals of all the three phases at all terminals. These fault indices were then compared with threshold value to detect and classify the faults and also identify the faulty terminal. The fault indices were used as inputs to the Fuzzy Inference System (FIS) for approximate fault location estimation from the respective terminals. Bior 1.5 wavelet has been chosen as mother wavelet as it has given the accurate results when compared with other members of wavelet family. The entire simulation was carried out in MATLAB environment within 110 km, 400 KV four-terminal transmission system, and the classification and location algorithms can be used as effective tools for real time digital relaying purpose as it has taken less than half cycle to detect the faults.

Keywords

Multi-Terminal Transmission, UPFC, Wavelet, Fault Index, Threshold Value, Fault Impedance, Fuzzy Inference System

How to Cite this Article?

Bhaskar, J. U., Kumar, G.R., and Ram, S.S.T. (2017). Wavelet-Fuzzy Based Digital Protection Scheme of Four-Terminal Transmission System in The Presence of UPFC. i-manager’s Journal on Electrical Engineering. 10(3), 18-29. https://doi.org/10.26634/jee.10.3.13411

References

[1]. A.H. Osman, and O.P. Malik, (2004). “Transmission line distance protection based on wavelet transform”. IEEE Trans. Power Del., Vol. 19, No. 2, pp. 515– 523.
[2]. Feng Liang, and B. Jeyasurya, (2004). “Transmission Line Distance Protection using Wavelet Transform Algorithm”. IEEE Trans. on Power Delivery, Vol. 19, No. 2, pp. 545-553.
[3]. T. Manokaran, and V. Karpagam, (2010). “Performance of distance relay estimation in transmission line with UPFC”. International Journal of Computer and Electrical Engineering, Vol. 2, No. 1, pp. 158–161.
[4]. P.K. Dash, A.K. Pradhan, and G. Panda, (2000). “Distance protection in the presence of unified power flow controller”. Electrical Power Systems Research, Vol. 54, No. 3, pp. 189-198.
[5]. Amany M, El-Zonkoly, and H. Desouki, (2011). “Wavelet entropy based algorithm for fault detection and classification in FACTS compensated transmission line”. Energy and Power Engineering, Vol. 33, No. 8, pp. 1368- 1374.
[6]. Gehan Gouda M.A., Abdel-Moamen M.A., and Gaber Shabib, (2004). “Power Flow Control using UPFC Device”. International Journal of Control, Automation and Systems, Vol. 3, No. 2, pp. 1-8.
[7]. P. Nagasekhar Reddy, (2014). “Simulation and Analysis of Fuzzy Logic based Unified Power Flow Controller connected to Transmission Line”. International Journal of Engineering Sciences & Research Technology, Vol. 3, No. 3, pp. 1372-1377.
[8]. L. Yusuf, and M.N Nwohu, (2015). “Effects of Unified Power Flow Controller (UPFC) on Distance Relay Tripping Characteristics in the North-Central Nigerian 330 kv Network”. Nigerian Journal of Technology, Vol. 34, No. 4, pp. 793-801.
[9]. C. Dinakaran, (2015). “Implementation of Shunt and Series FACTS Devices for Overhead Transmission Lines” International Electrical Engineering Journal (IEEJ), Vol. 6 No.8, pp. 2009-2017.
[10]. CH. Chengaiah, R.V.S. Satyanarayana, and G.V. Marutheswar, (2012). “Study on Effect of UPFC Device in Electrical Transmission System: Power Flow Assessment”. International Journal of Electrical and Electronics Engineering (IJEEE), Vol. 1, No. 4, pp. 66-70.
[11]. Ravi Kumar Goli, Abdul Gafoor Shaik, and S.S Tulasi Ram, (2015). “A transient current based double line transmission system protection using fuzzy-wavelet approach in the presence of UPFC”. International Journal of Electrical Power and Energy Systems, Vol. 70, pp. 91–98.
[12]. M. Khederzadeh, (2008). “UPFC operating characteristics impact on transmission line distance protection”. Proc. IEEE, PES General Meeting, Pittsburgh, pp. 1-6.
[13]. Ebha Koley, Khushaboo Verma, and Subhojit Ghosh, (2015). “An improved fault detection classification and location scheme based on wavelet transform and artificial neural network for six phase transmission line using single end data only”. Springer Plus, Vol. 4, No. 1, pp. 551, DOI 10.1186/s40064-015-1342-7.
[14]. Pankaj Khandelwal, and Bharat Modi, (2015). “Modeling, Simulation of UPFC and its Effect on Power System Protection”. International Journal of Emerging Research in Management &Technology, Vol. 4, No. 5, pp. 138-147.
[15]. M.J. Reddy, and D.K. Mohanta, (2007). “A waveletfuzzy combined approach for classification and location of transmission line faults”. International Journal of Electrical Power and Energy Systems, Vol. 29, No. 9, pp. 669–678.
[16]. Quanyuan Jiang, Bo Wang, and Xingpeng Li, (2014). “An Efficient PMU based fault location technique for multi transmission lines”. IEEE Transactions on Power Delivery, Vol. 29, No. 4, pp. 1675-1682.
[17]. J. Uday Bhaskar and S.S. Tulasi Ram, (2016). “Wavelet- Fuzzy based Multi Terminal Transmission System Protection Scheme in the presence of Statcom Controller”. International Journal of Fuzzy Logic Systems (IJFLS), Vol. 6, No. 3, pp.1-18.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.