Modeling Of Smoothing Reactor for HVDC Transmission System

L. Devi*, Ch. SaiBabu**
* Associate Professor,Intell Engineering College, Anantapur
** Professor, Department of EEE, J.N.T.U.College of Engineering, Kakinada.
*** Associate Professor, Department of EEE, J.N.T.U.College of Engineering, Kakinada
Periodicity:October - December'2010
DOI : https://doi.org/10.26634/jee.4.2.1277

Abstract

The HVDC transmission system is becoming ever more complex, further, demand for reliable supply of electricity is growing, increasing the need for a higher level of system reliability. A probable solution might be to incorporate controllable power components within the system. One such important is smoothing reactor or DC reactor. In this paper the effect of failure rate and repair time on expected capacity level or power transmission capacity of smoothing reactor at different inductance values with one, two and without spares is analyzed and compared. And also effect of number of spares on expected capacity level is presented.

Keywords

HVDC Transmission, Reliability, Dc Reactor, Expected Capacity Level.

How to Cite this Article?

L. Devi, C.H. Sai Babu and S. Siva Nagaraju (2010). Modeling of Smoothing Reactor for HVDC Transmission System. i-manager’s Journal on Electrical Engineering, 4(2), 47-54. https://doi.org/10.26634/jee.4.2.1277

References

[1]. Bhagawan reddy et al.; (2001). ”Application of Markov Modeling concepts for multi bridge and composite HVDC system reliability analysis” International conference on “Quality reliability and control “ organized by IETC, Mumbai center India and IIT Bombay, Mumbai, India during 26-28.
[2]. Billinton,R.,and Ahluwalia,D.S (1992). “Incorporation of a DC link in a composite adequacy assessmentcomposite system analysis” IEEE proc.C,Gen.,trans, &Distrib.,139,(3),pp 221-225
[3]. Billinton,R.,and Allan,R.N. (1988).”Reliability assessment of large electric power systems” (kluwer academic publishers, Boston,M.A,
[4]. Billinton,R.,and Sachdev,M.S (1968). “Direct current transmission system reliability evaluation”, Trans.CEA,7(3), pp 68-SP-170
[5]. Desrochers.G.,lefebvre,S.,rioux,B.,blanchard,m. (1987). ”Reliability assessment of HVDC transmission”, Canadian electric association report CEA,222 T 506,prepared by IREQ,
[6]. G.Descrochrs et al. (1985). V.A Method for the reliability evaluation of DC Links: CIGRE REPORT” session pp 14 01-14105
[7]. Direct current Transmission (Vol 1) by Kimbark.
[8]. Reliability evaluation of Engineering concepts by Roy Billinton Ronald N Allan
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Pdf 35 35 200 20
Online 35 35 200 15
Pdf & Online 35 35 400 25

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.