Abstract

This paper proposes renewable energy system interface with AC distribution system. AC grid interaction improves the efficiency of the system and reduces the power demand. In this paper, issues on renewable system interfaces with AC system are analyzed theoretically. In addition, this paper proposes a protective scheme for islanding detection. In current scenario islanding condition is dangerous for grid operators who were not aware of the power from the distributed generation supplying load still connected even though there is no power from the grid. For this reason, islanding condition must be detected and immediately stopped from producing power. For that aspects, this work proposed a new current injection control technique using microcontroller to detect the islanding condition and provide human safety and equipment protection

Keywords

Distributed Generation(DG), AC Grid, DC Grid, Islanding, PV, Wind, Controller.

How to Cite this Article?

Nagarajan, L.., Ali, A. N., and Arunkumar, S. (2018). Islanding Detection Technique for Grid Connected AC Distribution System. i-manager’s Journal on Future Engineering and Technology, 13(2), 45-51. https://doi.org/10.26634/jfet.13.2.13871

References

[1]. Alam, M. R., Muttaqi, K. M., & Bouzerdoum, A. (2014). A multifeature-based approach for islanding detection of DG in the subcritical region of vector surge relays. IEEE Transactions on Power Delivery, 29(5), 2349-2358
[2]. Bakhshi, M., Noroozian, R., & Gharehpetian, G. B. (2013). Anti-islanding scheme for synchronous DG units based on Tufts–Kumaresan signal estimation method. IEEE Transactions on Power Delivery, 28(4), 2185-2193.
[3]. Bejmert, D. & Sidhu, T. S. (2014). Investigation into islanding detection with capacitor insertion-based method. IEEE Transactions on Power Delivery, 29(6), 2485- 2492.
[4]. Bifaretti, S., Lidozzi, A., Solero, L., & Crescimbini, F. (2015). Anti-islanding detector based on a robust PLL. IEEE Transactions on Industry Applications, 51(1), 398-405.
[5]. Kim, J. H., Kim, J. G., Ji, Y. H., Jung, Y. C., & Won, C. Y. (2011). An islanding detection method for a gridconnected system based on the Goertzel algorithm. IEEE Transactions on Power Electronics, 26(4), 1049-1055.
[6]. Liu, F., Kang, Y., & Duan, S. (2007, February). Analysis and optimization of active frequency drift islanding detection method. In Applied Power Electronics Conference, APEC 2007-Twenty Second Annual IEEE (pp. 1379-1384). IEEE.
[7]. Paul, M. M. R., Mahalakshmi, R., Karuppasamy pandiyan, M., Bhuvanesh, A., & Ganesh, R. J. (2016). Fault Identification and Islanding in DC Grid Connected PV System. Circuits and Systems, 7(10), 2904-2915.
If you have access to this article please login to view the article or kindly login to purchase the article

Purchase Instant Access

Single Article

North Americas,UK,
Middle East,Europe
India Rest of world
USD EUR INR USD-ROW
Online 15 15

Options for accessing this content:
  • If you would like institutional access to this content, please recommend the title to your librarian.
    Library Recommendation Form
  • If you already have i-manager's user account: Login above and proceed to purchase the article.
  • New Users: Please register, then proceed to purchase the article.